Digital Ultrasonic Testing : UI-S7 Alpha

Digital Ultrasonic Testing : UI-S7 Alpha
More compact design for greater levels of practicality
Features
- High brightness LED monitor for indoor and outdoor usage.
- Dust-proof, drip-proof construction.
- Advanced architecture adopted.
- Size: 250 (W) x 160 (H) x 86 (D) mm
- Weight: Approx. 2 kg (incl. battery)
- Battery operating time: Approx. 10 hours (Depend on conditions)
UI-S7α DIGITAL ULTRASONIC INSTRUMENT
- Display
Screen size: 6.5″VGA a-Si TFT active-matrix Display area: 132.5 X 99.5
Pixels : 640(W) X 480(H)
A scan pixels: 424(W) X 316(H)
530(W) X 421(H) Enlargement - Size (mm)・Weight (kg)
250(W) X160(H) X86(D) Approx2kg Incl. Battery - Case (IP65 Drip-proof)
Reinforced ABS resin (front and rear) - Transmitter section
Output impedance: 50Ω or less
P.R.F.: Link with test range
Pulse rise up time: Less than 10ns
Wave form: Square wave pulse
Voltage: Low / Medium / High
Damping: 50 / 300Ω - Receiver section
Gain: 110dB (in step of 0.1dB)
Sensitivity: 80dB or better at 5MHz narrow band Input impedance: 50Ω±15% / 300Ω±15% Receiver amplification center frequency:
0.25/ 0.5/ 1/ 2/ 3/ 4/ 5/ 10/ 15/ 25MHz Amplifier linearity: ±3% Max - Time-base section
Test range:
1 to 14,556 mm in sound velocity 5900 m/s Adjustable delay: full scale to 3,000 μs ±5% Display time-base linearity: ±1% Max - Gate section
Delay range:
0 to full scale time range on the display
Gate marker width:
0 to full scale time range on the display Number of gate: 4
- Standard accessories
1, Li-Ion battery: UI02-LB66: 1
2, AC adapter: UIA345-15: 1
3, SD memory card: 1
4, Neck strap: UIS7NS: 1
5, Hand strap: UIS7HS: 1
6, Manual, Test certificate, Warranty: 1set - Frequency analysis function
Center frequency: 0.25 to 25MHz adjustable Display range: 50MHz max - Temperature
Ambient temperature: 0 to 45℃ (operation) -20 to 60℃ (storage) - Standard functionality
Measurement methods:
single probe / dual probe / transmission technique Wave form selections: DC / DC+ / DC- / RF Beam path measurement me
Peak / Up / First echo / Zero crossing / Peak up
Angle beam technique support function: 12 DAC max, refraction angle measurement
Data storage capacity: In attached 2GB SD card, 600 Conditions and 1,300 Images are stored - Power section
AC adapter: 100 to 240V±10% 50/60Hz±3Hz Battery: Li-Ion cell 1.
Battery operation time: approx. 10 Hours Charging time: approx. 2.5Hr 80%, 5H - Interfaces
Card slot: SD memory card
Connectors: USB (master)
USB (slave)
DC inlet
Earphone and microphone (Headset)
(JEITA RC-5240) - Optional extras
1, External charger: UICGS7
2, Soft case (protector): UIS7SC
3, Earphone and microphone
4, USB card reader