Visible Dye Penetrant Testing Materials Super-Check  
 
Use for detecting defects open to the surface of metals and nonmetals, and three-component product consisting of penetrant (P), remover (R) and developer (D). Organic solvent poisoning preveentive control-free and environment-friendly products are available.  
Specification
Compliant with or conformin to JIS,ISO,AMS and ASME
Application
Steel : Metal, Transportation Machinery, Electricity : Gas: Oil:
Chemical Plant, Machinery and parts,Mass Transportation, etc.
     

 

ADVENTAGES

  1. U-series materials secure the flaw detection accuracy equal or exceeding the test results as compared with the ordinary type materials in accordance with MIL Standards and ASME Code.

  2. These products are not in contravention of Japanese labour safety and hygiene and organic solvent toxicity prevention regulations.

  3. These products are not in contravention of Japanese specific chemical substances obstacle prevention regulations.

  4. Improved labour safety and sanitary conditions and working environment.

 

 

 

Super-Check “Type U” is dye penetrant inspection material which chemical compositions surpass the Japanese labour safety and hygiene and organic solvent toxicity prevention regulations. Its flaw detectability is equal or exceeds the test results as compared with the ordinary materials confirming to MIL Standards and ASME code.
This type has the following features in general.

  1. Flaw indication pattern formation becomes faster than the ordinary type materials  so far in use.

  2. Removability of Penetrant and Developer are improved.

Flash point of Penetrants are high, 70°C or more.

.

 

TYPICAL APPLICATIONS

Metallic Materials
Crack open to the surface of forgings, casting, weldments and rolled products (steel plates and sheets, steel rods and steel pipes and tubes) etc.,

 

Non-Metallic Materials

Crack open to the surface of synthetic resins, porcelains, ceramics and glass etc.,

 

INSTRUCTIONS
Pre-treatment
Remove dirt from the surface with Remover

Apply Penetrant
Apply Dye Penetrant on the surface to be tested and leave it for 5–20 minutes

Remove Pemetrant
Wipe off the excess Penetrant with cloth dampened with Remover

Developing
Apply Developer uniformly over the surface

Inspect the surface
Flaws will be revealed

Post-treatment

Remove Developer with Remover

 

 

Super-Check Product List

General Purpose

ST Series

Water washable

G III series

Low halogen/low sufur

T series

Non-inflammable

NU - G series

 

NU - C series

For high-temperature

H series

   
     
Pre-treatment : Remove dirt form the surface with Remover.
Apply Penetrant : Apply Dye Penetrant on the surface to be tested and leave if for five to twenty minutes.
Remove Penetrant : Wipe off the excess Penetrant with cloth dampened with Remover.
Developing : Apply Developer uniformly over the surface.
Inspect the surface : Flaws will be revealed.
Post-treatment : Remove Developer with Remover.

 

  SUPER CHECK

 
 

Copyright©2007 Marktec Corporation (Thailand). All rights reserved